LANCOM module

Signaling and control over ethernet (LAN) connection
Features
  • Ethernet network connection (LAN)
  • Emulates landline (TIP/RING) for alarm system
  • Automatic recognition of Contact ID and SIA FSK Level 1.2 reporting formats
  • Converting any Contact ID report codes to „push notification text message”
    and forwarding to smartphone applications
  • Remote monitoring connection to 2 independent SIA DC-09 IP receivers
  • Support of dynamic (DHCP) and static IP assignment
  • 2 contact inputs with unique signalling
  • Controlling of alarm panels with 2 relay (arm/disarm, up to 2 partitions)
  • Remote setup of alarm panels via internet (built in TTL/RS-232 serial ports)
  • Setup via PC program, USB connection (no router setup required)
  • Full remote management via WEB interface (configuration, diagnostics)
  • AES-128 encrypted communication option
Application
  • Transmission of alarm events to monitoring station and mobile App
  • Remote access, download and configuration of alarms systems
  • Monitoring of contact events, and remote control of relays

LANCOM –  enhance security with ethernet data transmission

The LANCOM is an advanced remote monitoring communicator using TCP/IP data transmission over the ethernet network.

The communicator (simulating a landline towards the alarm system receives) the Contact ID report codes from the alarm panel, then forwarding them as “push notification” to the users’ phones, simultaneously and instantly to all users.

The text of the notifications can be customized and tailored to the customer’s needs.

The connection between the unit and the application is checked every 30 seconds and in the event of a connection failure, the server sends a separate message the application to its users. This avoids the weak point of classic GSM communicators (call and SMS), the late detection of an expired SIM, blocked GSM communication or inoperability due to a faulty device.

The communication between the alarm and the LANCOM module can be in Contact ID (SIA DC-05 Standard) format, or in SIA FSK Level 1.2 (SIA DC-03 Standard) reporting format, depending on the communication settings of the alarm, done with automatic protocol recognition.

It has the additional advantage of being able to connect to a service server (IoT) in the background, allowing continuous remote access to the communicator via a WEB browser.

This means that even the connected alarm can be remotely accessed, configured and programmed at any time.

Signaling and control over ethernet (LAN) connection (ethernet data transmission)

Ethernet data transmission, ethernet data transmission

Features

  • Ethernet network connection (LAN) (Ethernet data transmission)
  • Emulates landline (TIP/RING) for alarm system
  • Automatic recognition of Contact ID and SIA FSK Level 1.2 reporting formats
  • Converting any Contact ID report codes to „push notification text message”
    and forwarding to smartphone applications
  • Remote monitoring connection to 2 independent SIA DC-09 IP receivers
  • Support of dynamic (DHCP) and static IP assignment
  • 2 contact inputs with unique signalling
  • Controlling of alarm panels with 2 relay (arm/disarm, up to 2 partitions)
  • Remote setup of alarm panels via internet (built in TTL/RS-232 serial ports)
  • Setup via PC program, USB connection (no router setup required)
  • Full remote management via WEB interface (configuration, diagnostics)
  • AES-128 encrypted communication option

Application

  • Transmission of alarm events to monitoring station and mobile App
  • Remote access, download and configuration of alarms systems
  • Monitoring of contact events, and remote control of relays

Technical details

Network connection

Ethernet 10BASE-T (IEEE802.3)

Alert notifications

Push notification (via Internet)

Inputs

2 (NO/NC)

Outputs

2 (NO)

Alarm communication interface

TIP/RING emulated landline (U=24V / I=25mA / Z=100-600 Ohm)

Alarm system communication protocol

Contact ID (SIA DC-05)

Remote monitoring protocol

SIA-IP (SIA DC-09)
Power supply
9-30V VDC

Other technical details

Rated current
100mA
Maximum current
130mA
Operating temperature
-10°C – +50°C

Dimensions

52 x 80 x 15 mm

Technical specifications

Network connection
Ethernet 10BASE-T (IEEE802.3)
Alert notifications
Push notification (via Internet)
Inputs
2 (NO/NC)
Outputs
2 (NO)
Alarm communication interface
TIP/RING emulated landline (U=24V / I=25mA / Z=100-600 Ohm)
Alarm system communication protocol
Contact ID (SIA DC-05)
Remote monitoring protocol
SIA-IP (SIA DC-09)
Power supply
9-30V VDC
Rated current
150mA
Maximum current
130mA
Operating temperature
-10°C – +50°C
Dimensions
52 x 80 x 15 mm
Weight50g